Photometric and
Performance Data

SERIES
R302


(2-light)


82% Total Luminaire
Efficiency

Zonal Lumen Summary

  Zone   Lumens   %Lamps   %Fixture

  0-30   1500     26       31
  0-40   2486     43       52
  0-60   4085     70       85
  0-90   4783     82       100
90-120   0        0        0
90-130   0        0        0
90-150   0        0        0
90-180   0        0        0
 0-180   4783     82       100




COEFFICIENTS OF UTILIZATION (CU) - ZONAL CAVITY METHOD
RF                                       20
RC       80               70             50           30           10        0
RW 70  50  30  10   70  50  30  10   50  30  10   50  30  10   50  30  10    0

0  99  99  99  99   97  97  97  97   93  93  93   89  89  89   85  85  85   83
1  91  88  84  81   89  86  83  80   82  80  77   79  77  75   76  74  73   71
2  84  77  72  68   82  76  71  67   73  69  65   70  67  64   68  65  62   61
3  77  69  62  57   75  67  62  57   65  60  56   63  58  55   61  57  54   52
4  71  61  55  49   69  60  54  49   58  53  48   56  52  48   55  50  47   45
5  65  55  48  43   64  54  48  43   53  47  42   51  46  42   49  45  41   40
6  61  50  43  38   59  49  43  38   48  42  37   46  41  37   45  40  37   35
7  56  46  38  34   55  45  38  33   44  38  33   42  37  33   41  36  33   31
8  53  42  35  30   51  41  35  30   40  34  30   39  34  30   38  33  29   28
9  49  38  32  27   48  38  31  27   37  31  27   36  31  27   35  30  27   25
10 46  35  29  25   45  35  29  25   34  28  25   33  28  24   33  28  24   23